Maintenance

Why Is Grease Leaking from Commercial Extraction Duct Joints?

Grease leaking from extraction ductwork is usually a sign that grease deposits are accumulating inside a commercial kitchen ventilation system and escaping through joints, seams, access panels or damaged connections. Common causes include poorly sealed duct joints, deteriorating gaskets, excessive grease build-up, unsuitable ductwork construction and inadequate cleaning access.

In commercial kitchens, extraction systems remove airborne grease, smoke, heat and cooking fumes. However, grease filters cannot capture every airborne particle. Some grease travels into the ductwork, where it can settle on internal surfaces and gradually accumulate.

When these deposits become substantial, liquid grease may collect around vulnerable connections. Leaks can then appear as dark stains, sticky residue or oily drips around duct joints and nearby surfaces.

For restaurant owners and facilities managers, this is more than a cleaning problem. Escaping grease may indicate an underlying ductwork defect or a potentially significant fire hazard.

Extractor Experts provides commercial kitchen extraction inspections, fault finding, repairs and maintenance support across London, Greater London and Surrey. Understanding the possible causes of grease leakage can help kitchen operators recognise warning signs and arrange appropriate professional assistance.

What Causes Grease to Leak from Commercial Kitchen Ductwork?

Commercial kitchen ductwork grease leaks can develop for several reasons. Some problems originate during installation, while others develop gradually through regular cooking operations, equipment deterioration or insufficient maintenance.

Identifying the actual cause requires more than examining the grease visible outside the duct.

1. Poorly Sealed Ductwork Joints

Ductwork joints connect individual sections of a commercial kitchen extraction system. These connections must be constructed and sealed appropriately for the operating conditions.

When a connection is not adequately grease-tight, accumulated grease can escape through gaps or imperfections.

Potential defects include incorrectly fitted flanges, unsuitable sealing materials, poorly completed welds and connections that have moved out of alignment.

A joint may appear secure externally while allowing grease to escape from its lower edge. This is particularly concerning when the affected section is concealed above a ceiling or within a service void.

2. Excessive Grease Accumulation Inside the Ducts

Grease-laden cooking fumes pass through the extraction canopy and filters before entering the ductwork.

Although effective grease separation reduces the amount reaching the ducts, some residue can still accumulate over time.

Heavy cooking activities, particularly frying, grilling and other grease-producing processes, may contribute to faster deposits.

As deposits accumulate, grease can collect in horizontal sections, low points and around ductwork connections. Existing weaknesses in the duct construction may then become visible through leakage.

The amount of grease present depends on several factors, including cooking intensity, filtration effectiveness, system design and cleaning history.

3. Damaged or Deteriorating Joint Gaskets

Some commercial extraction ductwork connections incorporate gaskets designed to maintain an appropriate seal.

These components must be compatible with the temperatures, grease and operating conditions of the system.

Over time, unsuitable or damaged gaskets may lose their sealing effectiveness.

Common issues include material deterioration, incorrect gasket positioning, compression problems and damage during previous maintenance work.

Once a gasket stops sealing properly, grease may escape from the connection.

Replacing a gasket without checking the underlying joint condition may not provide a lasting solution.

4. Poor Ductwork Layout or Installation

Ductwork design can influence where grease collects and how easily the system can be cleaned.

Poorly positioned joints, inappropriate duct gradients, inaccessible sections and unnecessary changes in direction can contribute to maintenance difficulties.

Where grease collects at low points, it may remain against vulnerable seams or connections.

A suitable extraction design should consider the cooking equipment, grease loading, airflow, duct construction, access requirements and applicable fire-safety considerations.

Professional assessment may be necessary when repeated leakage suggests that the ductwork arrangement itself is contributing to the problem.

5. Damaged Access Panels and Inspection Doors

Commercial kitchen extraction ducts require suitable access for inspection and cleaning.

Access panels and inspection doors create openings that must remain properly sealed when closed.

Grease may escape when an access panel has been incorrectly refitted, its gasket is damaged, or its securing mechanism no longer provides adequate compression.

Repeated opening during maintenance can also expose previously damaged seals or fittings.

If grease appears around an inspection door, the condition of the panel, gasket and surrounding ductwork should be assessed before further use.

6. Vibration and Movement Affecting Duct Connections

Commercial extraction systems contain mechanical components that can generate vibration during operation.

Excessive vibration may affect duct connections, supports and associated components, particularly where existing defects are present.

Possible contributing factors include fan imbalance, deteriorating bearings, loose supports and inadequate vibration isolation.

Persistent movement may worsen weaknesses in ductwork connections and contribute to leakage.

However, grease around a joint does not automatically mean that vibration is responsible. The fan, duct supports and affected connection must be assessed to establish the cause.

What Are the Warning Signs of Grease Leaking from Kitchen Extraction Ducts?

Grease leakage is not always immediately obvious. Early signs may appear on surfaces near the extraction system before visible dripping develops.

Kitchen operators should pay attention to unusual deposits, particularly around duct joints and areas that are normally dry.

Warning sign Possible explanation
Dark stains around duct joints Grease escaping through a seam or connection
Sticky residue on duct surfaces Accumulated grease migrating from a weak point
Oily drips beneath ductwork Liquid grease escaping from the extraction system
Grease around access panels Damaged or incorrectly fitted access-door seals
Repeated staining after cleaning An unresolved internal accumulation or joint defect
Grease appearing near duct supports Leakage travelling along external surfaces
Unusual vibration alongside leakage Possible mechanical movement affecting connections

These symptoms do not confirm a particular defect on their own.

For example, residue found near a duct joint may have travelled from another connection further along the system.

A professional inspection can help distinguish the original leakage point from the area where grease eventually becomes visible.

Is Grease Leaking from Extraction Ductwork Dangerous?

Yes. Grease leaking from commercial kitchen extraction ductwork can indicate a fire-safety concern and should be investigated promptly.

According to the Health and Safety Executive (HSE), grease and fat deposits inside commercial kitchen extraction ductwork can increase the risk of fire when exposed to an ignition source.

Cooking activities involving open flames, high temperatures and grease-laden fumes can increase the importance of effective extraction maintenance.

External grease leakage may also create secondary problems. Grease dripping onto floors or work surfaces can cause contamination and slipping hazards.

Where leakage affects electrical equipment, ceiling voids or other building components, additional risks may arise.

The severity depends on the location, amount of grease, ductwork condition and surrounding environment.

A small visible stain does not necessarily indicate a small internal problem. Equally, the presence of a leak alone does not establish the full extent of fire risk.

Where active dripping, heavy deposits or other serious warning signs are present, the affected equipment should be assessed urgently. Operations may need to stop until a competent person confirms that continued use is safe.

Technician inspecting commercial kitchen duct joints to identify grease leaking from extraction ductwork.

How Can You Identify the Source of a Ductwork Grease Leak?

Finding the original source of grease leaking from duct joints requires a systematic inspection.

Grease may travel along the underside of ductwork before dripping at a different location. As a result, the most visible stain may not identify the defective connection.

Examine the Visible Leakage Area

A preliminary visual assessment can identify the location of stains, deposits and obvious damage.

Kitchen staff can record observations without opening ductwork or disturbing electrical and mechanical equipment.

Photographs may help a maintenance contractor understand when and where the problem occurs.

Review Accessible Ductwork Connections

A competent technician can examine accessible joints, flanges, inspection doors and supports.

The inspection may reveal damaged seals, poor connections, corrosion, movement or other defects.

Concealed ductwork may require additional access to establish the condition of the affected sections.

Assess Internal Grease Deposits

Visible leakage can be associated with significant internal grease accumulation.

A specialist inspection may involve checking accessible internal surfaces and reviewing previous cleaning documentation.

The inspection should consider whether grease deposits are concentrated around a particular connection or distributed throughout the extraction system.

Investigate Related Mechanical Problems

Where vibration, unusual noise or reduced extraction performance accompanies leakage, the fan and associated mechanical components may also require examination.

This helps establish whether the leakage is an isolated ductwork defect or part of a wider extraction-system problem.

How Are Grease Leaks from Commercial Extraction Duct Joints Repaired?

The correct repair depends on the cause, location and condition of the affected ductwork.

A lasting solution should address both the visible leak and any underlying defect responsible for it.

Step 1: Inspect and Diagnose the Problem

A competent contractor should establish the likely source of the grease leakage.

This may involve examining duct connections, access panels, seals, supports and internal grease accumulation.

The contractor should also assess whether the defect affects any fire-resisting ductwork or other safety-critical components.

Step 2: Identify Suitable Repair Options

Once the problem has been diagnosed, the appropriate repair method can be considered.

Depending on the findings, work may involve replacing a compatible gasket, correcting an access-panel seal, repairing a defective joint or replacing a damaged ductwork section.

Some problems may require specialist welding or more substantial alterations.

Ordinary household sealants, adhesive tape and improvised patches should not be treated as reliable solutions for grease extract ductwork.

Repair materials and methods must be appropriate for the duct’s construction and required performance.

Step 3: Address Grease Accumulation

Where excessive internal deposits are present, specialist ductwork cleaning may be necessary.

Cleaning removes accumulated grease but does not automatically repair a defective connection.

Similarly, repairing a joint does not remove grease deposits elsewhere in the system.

Both issues should be addressed when they are found together.

Step 4: Check the Completed Work

After repairs, the affected section should be inspected and tested using methods appropriate to its construction and specification.

The assessment may include checking connection integrity, confirming access panels are correctly fitted and reviewing system operation.

Where required, the contractor should provide relevant repair and inspection records.

Can Grease Leaks Be Prevented Through Regular Maintenance?

Regular maintenance can reduce the likelihood of grease accumulation and help identify developing ductwork defects.

However, cleaning alone cannot prevent every leak, particularly when the ductwork has been incorrectly constructed or damaged.

An effective maintenance approach combines routine monitoring with appropriate specialist inspections.

Maintain Grease Filters and Canopies

Grease filters should be maintained in accordance with the equipment manufacturer’s instructions and the kitchen’s operating conditions.

Damaged, incorrectly positioned or heavily contaminated filters may allow more grease to enter the extraction system.

Kitchen staff should also monitor canopy surfaces and grease collection arrangements for unusual deposits.

Arrange Appropriate Ductwork Cleaning

Commercial kitchen extraction ducts require cleaning based on actual grease loading, operating hours, relevant industry guidance and any applicable insurance conditions.

A busy kitchen with significant grease production may require more frequent specialist cleaning than a facility with lighter cooking operations.

Cleaning frequency should not be based solely on the age of the installation.

Inspect Joints and Access Panels

Visible ductwork connections should be checked for signs of deterioration during appropriate maintenance inspections.

Recurring stains, damaged seals and loose access panels should be investigated rather than repeatedly wiped clean.

Maintenance records can help identify whether a particular joint has developed an ongoing problem.

Investigate Changes in Extraction Performance

Reduced airflow, unusual fan noise and excessive vibration may indicate problems elsewhere in the system.

These symptoms do not necessarily cause grease leakage, but they can justify a wider mechanical inspection.

Extractor Experts also provides commercial kitchen extraction system maintenance for businesses seeking support with the condition and operation of their ventilation equipment.

When Should Commercial Kitchen Ductwork Be Replaced Instead of Repaired?

Not every grease leak requires complete ductwork replacement.

A localised defect may be repairable when the surrounding ductwork is sound, accessible and suitable for continued operation.

Replacement may be more appropriate when there is extensive corrosion, repeated joint failure, significant physical damage or unsuitable ductwork construction.

Poor cleaning access and defects affecting required fire-resisting performance can also influence the decision.

The age of a system alone does not determine whether replacement is necessary.

A competent contractor should consider the condition of the existing installation, the extent of the defect and the feasibility of an appropriate repair.

Where a replacement section or wider alteration is required, suitable commercial ductwork installation should address the relevant construction, access and operational requirements.

Which UK Guidance Is Relevant to Grease Extract Ductwork?

Commercial kitchen extraction systems should be assessed against applicable legal requirements, the building’s fire-safety arrangements and relevant industry guidance.

The Health and Safety Executive explains that grease and fat deposits within kitchen ventilation ductwork can contribute to fires. It also recommends suitable ventilation design and regular cleaning to reduce accumulation.

The Building Engineering Services Association publishes DW/172 Specification for Kitchen Ventilation Systems, which provides industry guidance on commercial kitchen ventilation design, installation and maintenance.

BESA also publishes TR19 Grease, which provides industry guidance for inspecting, cleaning and managing fire risks associated with grease accumulation in commercial kitchen extraction systems.

These documents serve different purposes. Industry specifications and cleaning guidance should not automatically be described as standalone legislation.

The relevant requirements depend on the installation, building use, fire strategy and applicable contractual or insurance obligations.

Where a ductwork defect affects fire-resisting construction or other safety-critical features, a suitably competent specialist should determine the appropriate corrective work.

When Should You Contact a Commercial Kitchen Extraction Specialist?

Professional assistance is appropriate whenever grease leakage is recurring, difficult to locate or associated with visible ductwork damage.

An inspection is particularly important when grease appears around concealed ductwork, access panels or connections near other building services.

Kitchen operators should not attempt to open contaminated ducts, repair welded joints or modify ventilation equipment without suitable competence and safe working arrangements.

A professional assessment can help establish whether the problem requires cleaning, joint repair, ductwork replacement or further investigation.

Extractor Experts provides commercial extraction system repairs and fault-finding support for commercial kitchens in London, Greater London and Surrey.

Frequently Asked Questions

Why is grease leaking from commercial kitchen ductwork?

Grease usually leaks when deposits inside the extraction system escape through defective joints, damaged seals, poorly fitted access panels or other openings. Excessive internal accumulation can make existing defects more noticeable.

Is grease leaking from kitchen extraction ducts a fire hazard?

It can indicate a fire-safety concern because grease deposits are combustible. The actual risk depends on the amount of accumulation, system condition, location and potential ignition sources. Professional assessment is recommended.

Can a leaking extraction duct joint be sealed?

Some defective joints can be repaired, but the correct method depends on the ductwork construction and required performance. Ordinary tape or household sealant should not be used as a substitute for an appropriate professional repair.

How often should commercial kitchen extraction ductwork be cleaned?

Cleaning frequency depends on cooking activity, operating hours, grease accumulation and applicable guidance or insurance requirements. A competent specialist can help determine a suitable schedule based on the system’s condition and usage.

Does grease leakage mean the entire ductwork system needs replacing?

Not necessarily. Localised joint or gasket defects may be repairable. Replacement may be needed where there is extensive damage, repeated failure, unsuitable construction or other significant defects.

Conclusion: Address Grease Leakage Before It Becomes a Larger Problem

Grease leaking from extraction ductwork should never be dismissed as ordinary surface contamination.

Poorly sealed joints, deteriorating gaskets, excessive grease accumulation and damaged access panels are among the possible causes.

Identifying the original source and correcting the underlying defect can help prevent recurring leakage and support safer commercial kitchen operations.

Concerned about grease leaking from your commercial kitchen extraction system?

Extractor Experts provides commercial kitchen extraction fault finding, repairs, maintenance and ductwork services across London, Greater London and Surrey.

Call +44 7576 680389 or email info@extractorexperts.co.uk to discuss the problem and request a professional assessment.

Ventilation technician measuring static pressure in commercial extraction ductwork.

What Is Static Pressure in a Commercial Kitchen Extraction System?

Commercial kitchen extraction static pressure is the pressure exerted by air within a ventilation system, measured

Engineer inspecting a commercial kitchen extraction system

Who Maintains Kitchen Extraction in a Leased Restaurant?

Maintaining kitchen extraction in a leased restaurant depends on the commercial lease, the ownership of the

Engineer reviewing kitchen extraction planning submission information and ventilation drawings.

What Information Is Needed for a Kitchen Extraction Planning Submission?

Preparing a commercial kitchen extraction planning submission involves gathering clear information about the proposed cooking operation,